The %SWITCH in CL is used to control the ControlLevel indicators namely U1 thru U8. In your case, the CL program is checking whether U1=*ON and all other U indicators are off. Look for the RPG pgm. The RPG must be doing something to U1 to U8 indicators. Your RPG must be setting U1= ON. Some examples of %SWITCH are %SWITCH(10010000) makes U1 and U4 ON and the rest OFF. Hope this helps. - Venu +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].