× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



Hi Wayne,
Have you looked at MDCC from MAPICS?  It will provide edit checking for TA,
Job On and Off transactions, two-way communications to the shop floor and a
whole host of other features and functions.  There is a GUI and green
screen version (can be run simultaneously), as well as an RF menu that
contains many of the inventory transactions condensed onto a 16 x 20
character display for immediate implementation.

The GUI version has shop floor users in mind with its large buttons
designed for use on touchscreen displays.  We have integrated many
different TA terminals with MDCC, including units tied to barcode and mag
stripe readers in the event you use employee badges.

Please contact me if you would like more information.

Best regards,

Klaus Frost
Account Executive

Paper-Less, LLC
a subsidiary of Information Systems Engineering Inc.

Tel   262.567.9240  ext. 157
Fax  262.567.6588
klaus.frost@xxxxxxxxxxx
www.ise-erp.com
www.paper-less.net




|---------+----------------------------------------------------->
|         |           "Baldwin, Wayne (ALIE)"                   |
|         |           <Wayne.Baldwin@xxxxxxxxxxxxxxxxxxxx>      |
|         |           Sent by:                                  |
|         |           mapics-l-bounces+klaus.frost=ise-erp.com@m|
|         |           idrange.com                               |
|         |                                                     |
|         |                                                     |
|         |           11/11/2004 12:45 PM                       |
|         |           Please respond to MAPICS ERP System       |
|         |           Discussion                                |
|         |                                                     |
|---------+----------------------------------------------------->
  
>----------------------------------------------------------------------------------------------|
  |                                                                             
                 |
  |       To:       <mapics-l@xxxxxxxxxxxx>                                     
                 |
  |       cc:                                                                   
                 |
  |       Subject:  Data Collection Terminals                                   
                 |
  
>----------------------------------------------------------------------------------------------|





Hello all,

We are currently running Mapics XA R6 and have the PMC application
installed, collecting inventory, time and attendance and job off
transactions. We have two TX2001 Inducomp Data Collection Terminals
(from early 1900 I believe) that function as time clocks to gather time
and attendance transactions only. The other transactions are collected
on PC's throughout the shop using a custom software program written by a
consultant. We are in the process of installing and testing the iTera
Echo2 High Availability Software solution and would like to eliminate
these TX2001 terminals as they are not "IP" capable. The TX2001
terminals run HAL software and were interfaced to the PMC application by
the same consultant. What we would really like to do is replace the
TX2001 with an "IP" capable time clock that can connect to an Ethernet
network and pass the "fast clocking" time and attendance transactions
directly to the PMC application. Now, after all that is said, does
anyone use any type of devices connected to an Ethernet network that
would be able to perform the "TA" transactions required by the Mapics
PMC application?

Thanks in advance.

Wayne R. Baldwin
Senior Programmer Analyst
Smiths Aerospace LLC
Electronic Systems - L.I.
1000 Macarthur Memorial Highway
Bohemia,  NY  11716
T: (631) 467 - 5500  Ext 1258
F: (631) 467 - 5943

******************************************
The information contained in, or attached to, this e-mail, may contain
confidential information and is intended solely for the use of the
individual or entity to whom they are addressed and may be subject to legal
privilege.  If you have received this e-mail in error you should notify the
sender immediately by reply e-mail, delete the message from your system and
notify your system manager.  Please do not copy it for any purpose, or
disclose its contents to any other person.  The views or opinions presented
in this e-mail are solely those of the author and do not necessarily
represent those of the company.  The recipient should check this e-mail and
any attachments for the presence of viruses.  The company accepts no
liability for any damage caused, directly or indirectly, by any virus
transmitted in this email.
******************************************

_______________________________________________
This is the MAPICS ERP System Discussion (MAPICS-L) mailing list
To post a message email: MAPICS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/mapics-l
or email: MAPICS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/mapics-l.







As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.