|
I am trying to implement the PDM option for starting code/400 via PDM. When I take the new option, either of two things happen: 1. The PDM session stays inhibited for about 20 seconds, and then does nothing, or, 2. The code/400 window starts up on a co-worker's desktop My PDM option commands looks like this: Command . . . . . . . . . /* CODE Edit Member */ CALL PGM(QCODE/EVFCFDBK) PARM('37' 'Y' 'OS400A' '<LOCAL> CODEEDIT "<OS400A>&L/&F (&N)"') I have an unique current library. I have set the AS400 server information on my PC The communications server is running on my PC Any help would be greatly appreciated. Regards, Penny Lancor Technical Services Oakdene Group, Inc. "Barry W. Hoffman" <bwhoffman@natsem.com> To: CODE400-L@midrange.com Sent by: cc: "'cproctor@gartsports.com'" code400-l-owner@UUCPHO <cproctor@gartsports.com> ST.MCS.NET Subject: RE: Option in PDM for starting up code/400 04/24/01 02:39 PM Please respond to CODE400-L Chris, Here are the 3 PDM options that I use: CB: CALL QCODE/EVFCFDBK PARM('37' 'Y' 'OS400' '<LOCAL> CODEBRWS "<>&L/&F&N)"') CD: CALL QCODE/EVFCFDBK PARM('37' 'Y' 'OS400' '<LOCAL> CODEDSU "<>&L/&F&N)"') CE: CALL QCODE/EVFCFDBK PARM('37' 'Y' 'OS400' '<LOCAL> CODEEDIT "<>&L/&F (&N)"') The third parm needs to be the name of your Code/400 server. Also note &L not &I. Barry Hoffman National Seminars -----Original Message----- From: Chris Proctor [mailto:cproctor@gartsports.com] Sent: Tuesday, April 24, 2001 1:03 PM To: CODE400-L (E-mail) Subject: Option in PDM for starting up code/400 Hi all, I'm a newbie to code/400, but I read an email yesterday about setting up an option to start code/400 from PDM. The email said to set up the option like this: call qcode/evfcfdbk parm('37' 'Y' 'PCTCI' '<LOCAL> CODEEDIT "<> &l/&F(&N)" /M Y /N') So, all excited (it doesn't take much!) I tried it and it didn't work! : -( In fact it didn't do anything at all.....no error message, NOTHING! This is the first time we've ever tried this, so I'm not even sure the AS/400 is setup properly (if anything has to be configured on it). Can someone possibly point me in the right direction? Thanks, Chris Proctor Manager of Systems Integration MIS <<...OLE_Obj...>> 1060 Broadway Denver, CO 80203 Phone (303) 863-2280 Fax (303) 863-2263 mailto: cproctor@gartsports.com +--- | This is the CODE/400 Mailing List! | To submit a new message, send your mail to CODE400-L@midrange.com. | To subscribe to this list send email to CODE400-L-SUB@midrange.com. | To unsubscribe from this list send email to CODE400-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: larry@paque.net +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.