The THRU clause is only valid for level 88. See 'Data Description Entry
- Format 3' page 30 of the ILE COBOL Reference Summary. Levels 01
through 49 and 77 can only contain a single value.
01 Variables.
05 Var1 pic XX.
88 Lower-Half value '00' thru '49'.
88 Upper-Half value '50' thru '99'.
IF Lower-Half
statements...
EndIf.
Or
Evaluate True
When Lower-Half
statements...
When Upper-Half
statements...
When Other
statements...
End-Evaluate.
Basil Zangare
Nikon Inc
-----Original Message-----
From: cobol400-l-bounces@xxxxxxxxxxxx
[mailto:cobol400-l-bounces@xxxxxxxxxxxx] On Behalf Of
Santhamurthy_Veeraraghavan
Sent: Friday, August 26, 2005 7:46 AM
To: cobol400-l@xxxxxxxxxxxx
Subject: [COBOL400-L] VALUE CLAUSE in working storage
Hi,
Is it possible to have the VALUES as '0 thru 99' for a variable in
working storage and check for a condition in procedure division? Kindly
clarify?
Working-storage section.
77 VAR1 PIC 9(2) VALUES 0 THRU 99
Procedure division.
.
.
.
If var1 = 34
...statemetns..
Endif
Thanks & Regards,
Santha
DISCLAIMER:
This email (including any attachments) is intended for the sole use of
the intended recipient/s and may contain material that is CONFIDENTIAL
AND PRIVATE COMPANY INFORMATION. Any review or reliance by others or
copying or distribution or forwarding of any or all of the contents in
this message is STRICTLY PROHIBITED. If you are not the intended
recipient, please contact the sender by email and delete all copies;
your cooperation in this regard is appreciated.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.