MAdie,
Thanks for the info.. I hope you can join CLerysys so we can have someone
that has experience in ERPLX. Clerysys just started 3 years ago here in the
Philippines but it is very well established in other parts of the world.
Working here is fun. We have too many activities aside from work.
Hi Steve,
Also a big thanks for the info.. Hope I can also provide help in this forum
as you do..
Regards,
Eriq
From: Madie [mailto:bpcs.erp@xxxxxxxxx]
Sent: Wednesday, July 27, 2011 3:26 AM
To: eriq.l@xxxxxxxxxxxx
Subject: Re: [BPCS-L] ERPLX 8.3.4 Parameters
I am taking out the paramters from older verion of BPCS, so it may differ
from ERP LX.
ORD508B
IW7PLST DS
I 1 15 W1DCID
( Doc id as in ZPD file.)
I 16 30 W1KEY1
I 31 45 W1KEY2
I P 46 530W1KEY3
I P 54 610W1KEY4
I P 62 690W1KEY5
I P 70 770W1KEY6
I P 78 810W1ORDR
I 82 91 W1WSID
I 92 256 W1F165
Thanks,
On Tue, Jul 26, 2011 at 6:03 PM, Steve Keller <shk@xxxxxxxxxxxxx> wrote:
Source parms for LX 8.3.4...they are all the same for each pgm...do not have
source or object for PUR620B...there is a PUR620D with no parms passed in
BIL550B
Factor1+++++++Opcode&ExtFactor2+++++++Result++++++++Len++D+HiLoEq
*ENTRY PLIST
PARM RTPARM 1
PARM W7PLST
PARM W7SLST
ORD508B
Factor1+++++++Opcode&ExtFactor2+++++++Result++++++++Len++D+HiLoEq
*ENTRY PLIST
PARM RTPARM 1
PARM W7PLST
PARM W7SLST
ORD550B1
Factor1+++++++Opcode&ExtFactor2+++++++Result++++++++Len++D+HiLoEq
*ENTRY PLIST
PARM RTPARM 1
PARM W7PLST
PARM W7SLST
PUR520B
Factor1+++++++Opcode&ExtFactor2+++++++Result++++++++Len++D+HiLoEq
*ENTRY PLIST
PARM RTPARM 1
PARM W7PLST
PARM W7SLST
-----Original Message-----
From: bpcs-l-bounces@xxxxxxxxxxxx [mailto:bpcs-l-bounces@xxxxxxxxxxxx] On
Behalf Of Eriq Lorilla
Sent: Sunday, July 24, 2011 10:52 PM
To: 'BPCS ERP System'
Subject: [BPCS-L] ERPLX 8.3.4 Parameters
Hi,
Just trying my luck to get answers.
I have client that requires some of their reports modified but the problem
is they don't purchase the source code of ERPLX 834.
The programs are as follows;
BIL550B
ORD508B - Calling program is ORD705B
ORD550B1
PUR520B
PUR620B
Does anyone know the parameters pass to this programs.
Wish someone do have a source code for the calling programs. I just need the
parameters passed.
Thanks in advance.
--
This is the BPCS ERP System (BPCS-L) mailing list
To post a message email: BPCS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/bpcs-l
or email: BPCS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at
http://archive.midrange.com/bpcs-l.
CONFIDENTIALITY NOTICE: The information contained in this e-mail
communication and any attached documentation may be privileged, confidential
or otherwise protected from disclosure and is intended only for the use of
the designated recipient(s). It is not intended for transmission to, or
receipt by, any unauthorized person. The use, distribution, transmittal or
re-transmittal by an unintended recipient of this communication is strictly
prohibited without our express approval in writing or by e-mail. If you are
not the intended recipient of this e-mail, please delete it from your system
without copying it and notify the above sender.
--
This is the BPCS ERP System (BPCS-L) mailing list
To post a message email: BPCS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/bpcs-l
or email: BPCS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at
http://archive.midrange.com/bpcs-l.
As an Amazon Associate we earn from qualifying purchases.