On 01/04/11 5:16 PM, Pete Helgren wrote:
Can anyone tell me what section of code in ORD500 handles the F11 'Fold'Pete,
Option (I hope it isn't custom). I can't quite figure out what
subroutine toggles the display.
The F11 fold isn't BPCS code actually, it's handled automatically in the
system. The screen is designed in the DDS source member as previously
mentioned and an F-key is defined there also.
The data is sent to multiple lines of the Subfile Record but only the
first line is shown. When the unfold key (F11) is hit, the system
automatically reveals the "hidden" extra lines.
Bill
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].