Jerry,
When the load source drive on our RAID 5 protected 520 failed just a few weeks ago, I voiced the same concerns to our CE as you have but they weren't warranted. It is hot swappable and your system won't miss a beat. It's just like replacing any other drive. Now, if you have another drive go bad before unit 1 is replaced, you'd have some serious issues.
Bryan
iSeries Specialist
ECHO Outdoor Power Equipment
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx]On Behalf Of Jerry Adams
Sent: Friday, September 28, 2007 1:55 PM
To: Midrange-L
Subject: Disk Failure
Unit 1 in our four disk set (Raid5) failed. The IBM CE called and is bringing a replacement, but I've got a question or two before he arrives.
First, isn't unit 1 where the load source lives?
Second, are there any special steps in the recovery because of that?
Third, he said it was hot swappable. (I'm still going to kick everyone off of the system, though.) Is it really that easy?
Thanks.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].