Thank you, thank you, thank you! We had the first PTF, SI14126 installed already so I created the data area and all works. Gee the cover letter does not mention anything about the data area. Where or how did you find this out? Chris Bipes -----Original Message----- From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Forbes, Vincent Sent: Monday, December 06, 2004 11:37 AM To: 'Midrange Systems Technical Discussion' Subject: RE: CPYFRMIMP / CPYTOIMP Chris I had a similar problem. There are two options. 1. This is a temp fix that causes the CPYFRMIMP command to use the V5R2 version. 1) Apply ptf SI14126 2) CRTDTAARA DTAARA(QSYS/QCPFRMIMPF) TYPE(*CHAR) LEN(6) VALUE('CPV5R2') 2. PTF SI16043 as a perm fix. The data area above would need to be deleted before the PTF is applied.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.