> Perle 494 diskette drive was acting up. So I headed there (1 1/2 hours > one way with road construction...) with an extra 494E. We are on a frame > relay network, 494E's have an Ethernet card in them and the twin-ax > feature. Cisco routers. > So I swap things out, restore > the config, and - not exactly nothing, but close... The 494E comes > ready, I can ping it, the Control Unit on the AS/400 come active and the > terminals and printers do nothing... Terminals have left hand cursors... > All shows VARY ON PENDING. On QSYSOPR I get "CPF9366 Session start > request failed for device RM11 on controller RM080RMT." (just an example > for Device RM11 - I get this for ALL devices...) Very similiar to our network, except we're trying to have all 594 controllers. Did you use the *same* config file or create a new one? Normally when I saw these symptoms it was the WRKCFGL that didn't match the LU name (or was that the missing host table entry?). Anyway, make sure the name is in the config list and the IP address is the same as it was. Is RM080 the same name it used to be? Any errors on the Perle?
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].