I got this message last Friday afternoon when NOTHING should have been happening and QHST show basically nothing but this message for the time frame immediately preceding and following it: 09/21/01 16:30:27 CPF87D7 (Diagnostic) Cannot automatically select virtual device. Cause . . . . . : The VTM/FM cannot automatically select a virtual device. One of the following most likely occurred: the QAUTOVRT value was exceede or the device type specified for creation was not correct for this system.Recovery . . . : Please see messages previously listed in the job log to determine the exact error. Most likely, you will be able to correct this problem by doing one of the following: increase the allowed number of automatically selected virtual devices (the QAUTOVRT system value) or specify a different device type to be created for the virtual device. Aft making the correction, try the request again. Technical description . . . . . . . . : This message is sent by the server VTM/FM XPF module when it is not able to select a virtual device. One of the following most likely occurred: the server reached the limit specified by the QAUTOVRT system value, or the device type selected was not valid for the system. Does anyone have any idea what the heck this is ? Thanks, Chuck
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].