On 2011/4/13 4:45 PM, Henrik Rützou wrote:
if "line" is a varying field your code should be
callp write(fd: %addr(line)+2:%len(line));
If you are on 6.1, you can soft-code the "+2" by using the *data
parameter of %addr. That way, the code will also work if "line" has a
4-byte varying prefix.
callp write(fd: %addr(line:*data):%len(line));
--
This is the RPG programming on the IBM i / System i (RPG400-L) mailing list
To post a message email: RPG400-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/rpg400-l
or email: RPG400-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/rpg400-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].