<snip>
What about:
D SYSYMD S 6 0 inz(*SYS)
D SYSTIME S 6 0 inz(*SYS)
</snip>
You can't initialize this way.
RNF3430: Initial value *SYS does not match data type of field SYSTIME.
Initial value is ignored
Rob
-----Original Message-----
From: rpg400-l-bounces@xxxxxxxxxxxx [mailto:rpg400-l-bounces@xxxxxxxxxxxx]
On Behalf Of Booth Martin
Sent: December 14, 2007 11:32 AM
To: RPG programming on the AS400 / iSeries
Subject: Re: getting system date and system time
What about:
D SYSYMD S 6 0 inz(*SYS)
D SYSTIME S 6 0 inz(*SYS)
?
Another choice would be to not use the two fields at all, nut instead use
%date() & %time() where you are using SYSMYD & SYSTIME; e.g. eval DateField
= %date()
JDHorn@xxxxxxxxxxxxxx wrote:
Is there a better way to retrieve the system date and time than this,or
is this as good as any?
System date, not the job date.
D SYSYMD S 6 0 D SYSTIME S 6 0 /FREE SYSYMD = %DEC(%SUBST(%CHAR(%TIMESTAMP:*ISO0):3:6):6:0); SYSTIME = %DEC(%SUBST(%CHAR(%TIMESTAMP:*ISO0):9:6):6:0); /END-FREE C SETON LR Jim Horn
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].