|
Francis, Thanks for the reply. However, my question wasn't how to get the data into the character field from the numeric. My question was how to define the character field. What I'd like to be able to do is something like: D myNumFld s 10p0 D myDS DS qualified D myCharFld a like(myNumFld) And have myCharFld end up as a char(10) field. Charles Wilt -- iSeries Systems Administrator / Developer Mitsubishi Electric Automotive America ph: 513-573-4343 fax: 513-398-1121 > -----Original Message----- > From: rpg400-l-bounces@xxxxxxxxxxxx > [mailto:rpg400-l-bounces@xxxxxxxxxxxx] On Behalf Of Lapeyre, Francis > Sent: Wednesday, April 19, 2006 12:24 PM > To: 'RPG programming on the AS400 / iSeries' > Subject: RE: Easy way to define a DS char subfield the same > size as some numeric field? > > Use the %editc or %editw BIFs and %trim the result into a > character field. > > If you use a DS, that will make your numeric field packed, > which you may not > want. > > Francis Lapeyre > IS Dept. Programmer/Analyst > Stewart Enterprises, Inc. > E-mail: flapeyre@xxxxxxxx > > > > -----Original Message----- > From: rpg400-l-bounces@xxxxxxxxxxxx > [mailto:rpg400-l-bounces@xxxxxxxxxxxx] > On Behalf Of Wilt, Charles > Sent: Wednesday, April 19, 2006 10:12 AM > To: RPG programming on the AS400 / iSeries > Subject: Easy way to define a DS char subfield the same size > as some numeric > field? > > All, > > I've got a standalone field defined as packed(3,0). > > Is there an easy way to define a DS subfiled as char(3)? > > In other words, given any specific numeric field, how can a define a > corresponding character field large enough to hold the > numeric data without > having to hardcode the subfield size? > > The DS is used to send out an email message. If there isn't > an easy way to > do what I want, I'll just get rid of the DS altogether and > use eval + some > bifs to build the message. That may be a better option, but for > instructional purposes, I would like to show a DS without > hard coded sizes. > > > Thanks, > > Charles Wilt > -- > iSeries Systems Administrator / Developer Mitsubishi Electric > Automotive > America > ph: 513-573-4343 > fax: 513-398-1121 > > > -- > This is the RPG programming on the AS400 / iSeries (RPG400-L) > mailing list > To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, > unsubscribe, or > change list options, > visit: http://lists.midrange.com/mailman/listinfo/rpg400-l > or email: RPG400-L-request@xxxxxxxxxxxx > Before posting, please take a moment to review the archives at > http://archive.midrange.com/rpg400-l. > -- > This is the RPG programming on the AS400 / iSeries (RPG400-L) > mailing list > To post a message email: RPG400-L@xxxxxxxxxxxx > To subscribe, unsubscribe, or change list options, > visit: http://lists.midrange.com/mailman/listinfo/rpg400-l > or email: RPG400-L-request@xxxxxxxxxxxx > Before posting, please take a moment to review the archives > at http://archive.midrange.com/rpg400-l. > >
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.