Hi Martin

"Is there any opcode that exits the whole program from within a procedure?"

The short answer is no, you have to issue a RETURN operation from the
mainline of the programs initial procedure to exit the program, and have
*INLR set to close the program down.

You've got the right idea in your handler procedure, but you will also need
to issue returns at each previous level of your invocation stack so that you
back down to the mainline procedure.

Hope that helps

All the best

Jonathan
www.astradyne-uk.com



As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].