Remember this is RPGIII, In the File condition field, it has UC. So, YES.
RPower@xxxxxxxxxx wrote:
It almost sounds to me like the program is trying to open the printer file, not your code. Is the TICKET file specified as USROPN?
Ron Power
Programmer
Information Services
City Of St. John's, NL
P.O. Box 908
St. John's, NL
A1C 5M2
Tel: 709-576-8132
Email: rpower@xxxxxxxxxx
Website: http://www.stjohns.ca/
___________________________________________________________________________
Success is going from failure to failure without a loss of enthusiasm. - Sir Winston Churchill
Justin Houchin <justinh@xxxxxxxxxxxxx> Sent by: rpg400-l-bounces@xxxxxxxxxxxx
06/16/2004 01:54 PM
Please respond to
RPG programming on the AS400 / iSeries <rpg400-l@xxxxxxxxxxxx>
To RPG programming on the AS400 / iSeries <rpg400-l@xxxxxxxxxxxx> cc
Subject Re: I/O operation was applied to closed file...
Posting the code would not be a good idea, this is an ERP system that I have integrated a modification into. Has anyone seen a problem like this before?
RPower@xxxxxxxxxx wrote:
Any way to see the code? Would you be able to paste it here?
Ron Power Programmer Information Services City Of St. John's, NL P.O. Box 908 St. John's, NL A1C 5M2 Tel: 709-576-8132 Email: rpower@xxxxxxxxxx Website: http://www.stjohns.ca/
___________________________________________________________________________
Success is going from failure to failure without a loss of enthusiasm. -
Sir Winston Churchill
Justin Houchin <justinh@xxxxxxxxxxxxx> Sent by: rpg400-l-bounces@xxxxxxxxxxxx
06/16/2004 01:27 PM
Please respond to
RPG programming on the AS400 / iSeries <rpg400-l@xxxxxxxxxxxx>
To RPG programming on the AS400 / iSeries <rpg400-l@xxxxxxxxxxxx> cc
Subject Re: I/O operation was applied to closed file...
I tried using the FEOD command, my printer file now will not ouput any spool files. I am still puzzled that the program will execute one time correctly, but when you feed it another work order number, it never makes it past the *ENTRY PLIST command before sending the message to QSYSOPR, it has even hit the code to OPEN or even write to the printer file. The program does just use the RETRN command and does not seton the LR indicator. And there is no *INZSR subroutine. Any ideas?
Thanks, Justin
CWilt@xxxxxxxxxxxx wrote:
It might. Assuming the problem has something to do with an error in where/how the file is being opened and/or closed.
If you use FEOD you can/must get rid of the open and closes along with
the
USROPN if you are using it.
Charles
-----Original Message----- From: Justin Houchin [mailto:justinh@xxxxxxxxxxxxx] Sent: Monday, June 14, 2004 10:29 AM To: RPG programming on the AS400 / iSeries Subject: Re: I/O operation was applied to closed file...
Is this going to fix my problem?
CWilt@xxxxxxxxxxxx wrote:
Justin,
Why close the file?
Try using the FEOD op-code to end the current printer file
and start a new
one.
It will be easier and perform better.
HTH, Charles
-----Original Message----- From: Justin Houchin [mailto:justinh@xxxxxxxxxxxxx] Sent: Monday, June 14, 2004 8:59 AM To: rpg400-l@xxxxxxxxxxxx Subject: I/O operation was applied to closed file...
Hi Everyone,
I have a program that writes to two printer files. The first file QSYSPRT gets opened, written, and closed. The second printer file TICKET, gets opened, written, and closed after the QSYSPRT
file. The
program this code runs in is a asynchronous job that reads
a message
queue, so the job never ends. History: The program will receive a work order number from the message queue and print some paperwork using QSYSPRT and TICKET printer files. The problem: When I first
start the
job and send a work order number to the message queue, the program picks up the number and prints the paperwork perfectly, if I send another work order number to the message queue the program sends a
message to the
QSYSOPR message queue that the program tried to write to a closed file TICKET. I have double checked the code and I feel the
TICKET file is
being closed after the first work order is printed. I created a debug breakpoint at the start of the program. The program breaks at the beginning of the program when the first work order is read.
But when
the second work order is read, the program does not break and a message is sent to QSYSOPR. I am stumped. Any help would highly be appreciated.
Justin
--
This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing list
To post a message email: RPG400-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/rpg400-l
or email: RPG400-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/rpg400-l.
--
This is the RPG programming on the AS400 / iSeries
(RPG400-L) mailing list
To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/rpg400-l or email: RPG400-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
--
This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing list
To post a message email: RPG400-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/rpg400-l
or email: RPG400-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/rpg400-l.
--
This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing
list
To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/rpg400-l or email: RPG400-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
--
This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing
list
To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/rpg400-l or email: RPG400-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
This OutBound email has been scanned for Viruses
--
This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing
list
To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/rpg400-l or email: RPG400-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
-- This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing list To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/rpg400-l or email: RPG400-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
This OutBound email has been scanned for Viruses -- This is the RPG programming on the AS400 / iSeries (RPG400-L) mailing list To post a message email: RPG400-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options, visit: http://lists.midrange.com/mailman/listinfo/rpg400-l or email: RPG400-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at http://archive.midrange.com/rpg400-l.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].