>> I tried to run CRTSRVPGM, relisting all the *MODULEs including the new one, but all the old *MODULEs threw a "Definition supplied multiple times for symbol" error because the old service program is listing them already. UPDSRVPGM sadly only allows you to replace a module (not add). You need to do CRTSRVPGM. I can only imagine that you have the modules used in another service program (that is being linked to this one) listed in the binding directory. Can't think of any other reason why you'd get dups. Jon Paris Partner400
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].