Martin Rowe
>>I think my beef is that it's doing things behind my back. I like clear,
>>concise code that's easy to follow, and easy to maintain.




I understand where you're at Martin,  However the OS "Doing things behind
my back"  is a
matter of degrees.

When it initializes standalone fields at start up,  it's doing things
behind your back,
When it opens files at start up or when it rolls between existing SFL pages
it's doing
things behind your back.

When you use Input Primary and Level indicators,  it's not doing things
behind your back,
It's an agreement you made with the OS,

You in essence said,  "Hey OS,  You read the records for me and if you see
my control fields
change,  Let me know will ya? ""

Well the L1 L2 level indicators are just the messengers from the OS to you,

Don't blame the messenger.  It could have been implemented using some other
variable saying

"Hey Martin,  Your Control Field Changed !!"

But it was implemented with L1 L2....   A Rose is a Rose....


Just different ways to look at it.

John Carr



As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.