Jim wrote:
>>I'm one of the programmers who doesn't like using indicators in
>>new RPG IV code. Yet, I find myself having to use them in a few
>>cases, notably the opcode TEST.
>>C *YMD TEST(D) SomeDate 99
>>C If NOT *IN99
>>...
>>Is there yet a workaround this where we don't have to use indicators
>>yet?
You can also this at V5R1, Jim:
D Variable S 8P 0 Inz(20011332)
/Free
// Test if packed numeric field contains valid date value
Test(DE) *Iso Variable; // Invalid ISO value
If %Error;
Dsply 'Invalid Date' '*REQUESTER';
Endif;
*InLR = *ON;
/End-Free
Brian Parkins
+---
| This is the RPG/400 Mailing List!
| To submit a new message, send your mail to RPG400-L@midrange.com.
| To subscribe to this list send email to RPG400-L-SUB@midrange.com.
| To unsubscribe from this list send email to RPG400-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].