Hans, At 12:24 PM 8/11/99 -0700, you wrote: >> So, please consider and choose one of the following options: >> 2) Allow EVAL and CALLP to be omitted: >> >> CF KeepLooping = *ON >> CF dow KeepLooping >> CF read MasterFile >> CF if %eof >> CF HandleEndOfFile() >> CF endif >> CF enddo I vote for #2. Unless you're going to start using special characters in the opcodes (which would make the code ugly, IMHO) there's no way you can guarantee not having a clash. But a simple scan / replace can usually solve the problem pretty easily. Or allow the EVAL opcode for those cases that the variable becomes an opcode. -mark +--- | This is the RPG/400 Mailing List! | To submit a new message, send your mail to RPG400-L@midrange.com. | To subscribe to this list send email to RPG400-L-SUB@midrange.com. | To unsubscribe from this list send email to RPG400-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].