You have to use the ACQ op code in the C-specs to acquire a signed off terminal. Also, the MAXDEV keyword in the H-specs specifies the maximum number of devices you want to acquire. >Haai Friends, > >I am trying to acquire many screen devices in my RPG program and write my >display record format to that devices. This becomes possible when I am >acquiring one device after releasing the previous device. Is it that I can >not write a record format to all the devices at a time whichever are in SIGN >ON DISPLAY mode?. > >If yes, pl. tell me. That will be helpful to my project. > > > >With thanks, > >Kannan Charlie Massoglia, Massoglia Technical Consulting, Inc. PO Box 1065, Okemos, MI 48854, USA 517-676-9700 Fax: 517-676-1006 EMAIL: cmassoglia@voyager.net * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * This is the RPG/400 Discussion Mailing List! To submit a new * * message, send your mail to "RPG400-L@midrange.com". To unsubscribe * * from this list send email to MAJORDOMO@midrange.com and specify * * 'unsubscribe RPG400-L' in the body of your message. Questions should * * be directed to the list owner / operator: david@midrange.com * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].