Yep the ASP we see as an option as I mentioned. It's just going to require more disks and some management there.

- Larry "DrFranken" Bolhuis

www.Frankeni.com
www.iDevCloud.com - Personal Development IBM i timeshare service.
www.iInTheCloud.com - Commercial IBM i Cloud Hosting.

On 3/3/2016 10:13 AM, Steinmetz, Paul wrote:

I have a similar issue, but the restore is done on a different LPAR.
BRMS allows you to force the ASP on the RSTLIBBRM
Auxiliary storage pool . . . . . > &UPRSTASP

Specifies whether libraries and objects are restored to the auxiliary
storage pool from which they were saved or to a different auxiliary
storage pool. Libraries and their contained objects can only be
restored to the system (1) auxiliary storage pool, a basic user (2-32)
auxiliary storage pool, a primary auxiliary storage pool or a secondary
auxiliary storage pool.

I created a 2nd ASP, keeping SSD and spinny separate.
I have the ability on the RSTLIBBRM if I want the library on SSD or on spinny.

Paul

-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Rob Berendt
Sent: Thursday, March 03, 2016 10:07 AM
To: Midrange Systems Technical Discussion
Subject: Re: Force Restore of files tagged UNIT(*SSD) to Spinny Disk

Good ideas Darren.
However,
1 - If not all files were changed then you have to keep track of whom to change back to SSD. Not impossible, just more work.
2 - In a DR situation you have to change the attribute after the restore because they would have been saved with the wrong attribute.


Rob Berendt
--
IBM Certified System Administrator - IBM i 6.1 Group Dekko Dept 1600 Mail to: 2505 Dekko Drive
Garrett, IN 46738
Ship to: Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com





From: Darren Strong <darren@xxxxxxxxx>
To: Midrange Systems Technical Discussion <midrange-l@xxxxxxxxxxxx>
Date: 03/03/2016 09:54 AM
Subject: Re: Force Restore of files tagged UNIT(*SSD) to Spinny
Disk
Sent by: "MIDRANGE-L" <midrange-l-bounces@xxxxxxxxxxxx>



One more thought. We used to have a mix of SSD and spinnys. We no longer
have that, so I cannot experiment. However, I recall there was a time
when
I could alter the UNIT attribute and the move would be made immediately.
There were other times (either through OS upgrades or PTFs) when I would
change the attribute and it required a save/restore to make the effect
felt
(never tried your RGZPFM).

Anway, I see two possible solutions based on what you find to be the
behavior. If the UNIT attribute happens immediately, you do the restore
and then change the attribute. If it is delayed, then you change the
attribute on the source machine, save, and then change the attribute back,
theoretically not affecting the SSD status on the source machine, since
the
affect is not immediate.

Have a customer with SSD and Spinny. Many files in production DB tagged
UNIT(*SSD). Monthly they restore production backup (about 1TB) to
training library and you guessed it all those files pile on the SSDs
overfilling them. Any idea how to make the Restore override the
UNIT(*SSD) and put them on spinny disk?


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.