GO BRMS
11. Policy administration
1. System policy
7. Change IPL controls
Type choices, press Enter.
IPL after process . . . . . . . . . . . *NO *YES, *NO
How to end . . . . . . . . . . . . . *CNTRLD *CNTRLD, *IMMED
Delay time, if *CNTRLD . . . . . . . 1200 Seconds, *NOLIMIT
Restart after power down . . . . . . *YES *YES, *NO
IPL source . . . . . . . . . . . . . *PANEL *PANEL, A, B
IPL restart type . . . . . . . . . . *IPLA *FULL, *IPLA, *SYS
Earliest time to allow an IPL . . . . 0:01 HHMM
Latest time to allow an IPL . . . . . 7:00 HHMM
Paul
-----Original Message-----
From: MIDRANGE-L [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jerome Draper
Sent: Saturday, November 28, 2015 1:57 PM
To: midrange-l@xxxxxxxxxxxx
Subject: IPL limits
Anyone know where this time is controlled?
We have specified for the system to IPL after a full system backup in BRMS.
Thanks,
Jerry
Job . . . : MONTHLY User . . : DRAPERJ Number . . . . : 423204
Date sent . . . . . . . . : 11/25/15 Time sent . . . . . . : 22:39:01
Program . . . . . . . . . : Q1ARBK Area . . . . . . . . . : *BKU
Message . . . . : IPL cannot be started.
Cause . . . . . : Current time 22:39 is not within IPL limits 00:01 and
07:00.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe, or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.