Roberto,

Interesting solution there. I hope it actually works and in theory it should because all you are doing is correcting the RAID set. Obviously doing anything more than that to those drives is fatal to that system.

As to moving the drives you can move them to and from the CEC if you keep them under the right controllers. If you move them to a newer controller that modifies the striping then yeah that's an issue. It has nothing to do with 4 or 5 or 6 drive disk cages. So long as the drives are connected to the same RAID card it matters not on which port or in which slot they exist. So moving for example from a CEC with 8 drives to a 5095/0595 with 12 slots you can put them anywhere. Exception of course is the load source disk with it's specific rules.

As you also suspect with SAS it's all different. There is no specific spot for the load source but us traditionalists like to keep it on the first drive in the drawer connected to the first port on the RAID card just so we know where the bugger is.

To your questions to about SOP without having another system? Yeah that's a tough one. Either you replace it before you power down, which you had no opportunity to do since it was alive when you powered it down. Or you bonk it to get it going again, which certainly doesn't always work. Or you have a high enough function RAID card that will IPL with the drive dead. Or you move the drives temporarily to another LPAR (which is much the same as you're doing now but without the physical move.) Or you restore from backup. (Ugh!)

I hope it all works out well for yoU!

- Larry "DrFranken" Bolhuis

www.Frankeni.com
www.iDevCloud.com - Personal Development IBM i timeshare service.
www.iInTheCloud.com - Commercial IBM i Cloud Hosting.

On 8/22/2015 7:32 PM, Roberto José Etcheverry Romero wrote:

Hi All,

After doing somebody a favour and exchanging a 0595 for a 5095 (wanted to
have everyting in the rack instead of racked CEC and tower EXP) i ended up
running around due to a failed load source drive (drive died when system
spun down and the dust removed), failed to do D-Type IPL due to a missing
7212 (seems it never got used after the initial setup)
I brought the drives to my lab, put them into an installed machine and
found the dead drive. I'm now rebuilding before moving those disks (and
controller) back to the original machine.
Here is my question:
What would be the SOP for rebuilding that disk, without having an
additional expansion with the same kind of slots and installed LIC? (found
out that moving from 520 CEC to 5095 is possible but not backwards, if 6
disks are present on a single cage, it dies with XXXX9023)
I haven't found a "rebuild disk drive" in the D-Type IPL...
I haven't tried it yet but i think SAS disks are exempt from the whole
ordeal since the SAS Controllers no longer care in which slot the LS is
(which may mean that it distributes the info...)
In any case, if i can find another way great and if not, i already have one
way.

Best Regards,

Roberto


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.