The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.
And that is the exact same SRC you previously posted.
http://archive.midrange.com/midrange-l/201412/msg00392.html
As far as the qiplsTs system value a 2 indicates 2=Restart IPL. This
seems to indicate:
"Restart IPL. IPL occurred when the Power Down System
(PWRDWNSYS) command with RESTART(*YES) was issued. "
At least according to the help on that system value.
I issued one last night on a 7.2 machine and DSPLOG shows this:
CPI0995-PWRDWNSYS command issued with parameters specified.
CPF0901-PWRDWNSYS command issued by user ROB and is being processed.
CPF0930-PWRDWNSYS command in progress.
And if you press help on the CPI0995 you will see:
The Power Down System (PWRDWNSYS) command was requested by
job 013487/ROB/DSP010000 with the following parameters specified:
-- How to end *CNTRLD
-- Delay time 120
-- Restart options *YES *SYS
-- IPL source *PANEL
-- End subsystem option *DFT
-- Timeout option *CONTINUE
-- Confirm *ENVVAR
-- Image catalog
Personally, I did a WRKACTJOB SBS(QCTL) and did a 5 on the subsystem
itself and then a 1 to see it's start time. Dropped back a few minutes
from that in my DSPLOG and that's how I found these messages.
As far as
<snip>
but vendor package is not running
</snip>
You may want to see how that is traditionally started. Does one have to
manually start something? Did some subsystem autostart job fail? Does
this vendor package rely upon some now failing piece of hardware?
Rob Berendt