Use the replacement procedure in the HMC for the cards. Since they are
different you might see some complaining about the RAID set being from a
different card.


BIG CAVEOT!!!!!! Be really, really, really, no really sure you have
flushed the cache on that card before you swap it. If it's not flushed,
reload time.......

--
Jim Oberholtzer
Chief Technical Architect
Agile Technology Architects


-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Evan Harris
Sent: Thursday, February 20, 2014 4:42 PM
To: Midrange Systems Technical Discussion
Subject: Re: Replacing a pair of 5903s with a pair of 5913s

The system is HMC Managed


On Fri, Feb 21, 2014 at 11:40 AM, Steinmetz, Paul
<PSteinmetz@xxxxxxxxxx>wrote:

The process may be slightly different depending if your HMC managed.
If HMC, wizard will step you through.
If nonHMC, then you need to check concurrent maintenance process for
nonHMC managed.

-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:
midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Evan Harris
Sent: Thursday, February 20, 2014 5:08 PM
To: Midrange Systems Technical Discussion
Subject: Replacing a pair of 5903s with a pair of 5913s

Hi All

I'm replacing a pair of 5903's with a pair of 5913's in a 750;
intention is to allow an additional 5887 tray to be attached to the
system.

The 5903 cards are housed in a 5877 and the partition owning the cards
will be powered down to effect the change. There are cards owned by
other partitions in the 5877.

Do I need to power off the entire 5877 and therefore shut down the
other partition as well, or am I OK to replace the cards once the
owning partition is powered down ? Should I/can I power off the
individual slots as part of the install ?

The pre-reqs page also tells me to verify the firmware on the 5877 is
at the right level - does anyone have any hints ore references as to
how I would determine this ?

The partition the cards will be assigned to is running V6R1M1 and will
be updated to resave level M prior to the hardware change, along with
the latest cume, hiper and group PTFs.

Any and all advice appreciated.

--

Regards
Evan Harris
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take
a moment to review the archives at http://archive.midrange.com/midrange-l.

--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing
list To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe,
unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take
a moment to review the archives at
http://archive.midrange.com/midrange-l.





As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.