On Fri, Oct 18, 2013 at 4:20 AM, Steinmetz, Paul <PSteinmetz@xxxxxxxxxx>wrote:

Since migrating from ANYNET to EE
SAVRSTOBJ from LPAR A to LPAR B results in failure, intermittently
Strpasthr from A to B also fails.
Strpasthr from B to A works.

On B, Object Connect retries for 2 hours, before reporting the error.
ObjectConnect internal error, function code F5, return code BF.

On A, error occurs, 30 minutes earlier.
CPF3808 Diagnostic 30 10/17/13 04:21:46.431277
QSRSVDEQ QSYS 0388 QSREVTHD QSYS 03FD
Message . . . . : Save file OBCSAVF
in QTEMP not complete.
Cause . . . . . : An error occurred
during the save operation. Recovery . .
. : Do not use the save file for
restoring because the restore operation
may not end normally. See message
CPF389C for corrective action.
CPF389C Escape 30 10/17/13 04:21:46.431538
QSREVTHD QSYS 0568 QSVRSINT QSR 00DC
Message . . . . : ObjectConnect
internal error, function code F4, return
code BF.
Cause . . . . . : An error occurred
during an ObjectConnect communications
request. Recovery . . . : Try
the request again. See the Backup and
Recovery - Basic book, SC41-4304
for an explanation of the codes. If the
problem persists, report the
problem using the Analyze Problem (ANZPRB)
command.


It appears the "timers" are different on A and B,
LPAR A tries for 90 minutes.
LPAR B tries for 120 minutes.

Sometimes, the issue resolves itself, no interaction done.
Other times, varying off/on EE controller on A that points to B "appears"
to resolve the issue.

Open PMR with IBM, nothing yet.

Could it be a configuration issue.

Anyone experience similar issue?


Thank You
_____
Paul Steinmetz
IBM i Systems Administrator

Pencor Services, Inc.
462 Delaware Ave
Palmerton Pa 18071

610-826-9117 work
610-826-9188 fax
610-349-0913 cell
610-377-6012 home

psteinmetz@xxxxxxxxxx<mailto:psteinmetz@xxxxxxxxxx>
http://www.pencor.com/

--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/midrange-l.





As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.