× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



It's not that I missed it (not entirely), it's just that I assumed that both boxes were on the same APPN network (and I do know what ASSUME does - I've learned that lesson many times :-) ). I now have to look into the configurations that you have so conveniently laid out for me. Thank you (and Larry Bolhuis) for the info.


******************************************
Don Wereschuk
ISD - Programmer/Analyst
Simcoe Parts Service Inc.
Phone: 705-435-7814 Ex: 302
Fax: 705-435-5029
mailto:dwereschuk@xxxxxxxxxxxxxxx
******************************************
If I'd have done what I said I should have done,
then I'd be sitting here saying I should have done what I did do.





-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Jim Oberholtzer
Sent: Friday, September 06, 2013 9:23 AM
To: Midrange Systems Technical Discussion
Subject: Re: Data Transfer

Ah, you may have missed the restriction number 4 in the documentation, "Both systems intended to participate int he save and restore operation must be connected to the same APPN network"

That requires the network attributes to be set correctly (my even require an IPL) and come communication lines and devices. Even I can set it up so it does not take genius to do, but must be done correctly. So:

Network attributes:
System name: mysystem
Local Location name: mysystem
Default Local Location: mysystem
Nodetype: *NETNODE
Allow Any net: *NO
Allow APPN Virtual Support: *YES
Allow HPR Transport *YES
Virtual Controllers Auto Create: 100 ( I usually use 100, set to taste )
I set the country ID as well: US

These are the target controllers
Controllers:
CRTCTLAPPC CTLD(ENTERPRISE)
LINKTYPE(*VRTAPPN)
AUTODLTDEV(10000)
TEXT('Enterprise Extender Controller')
CRTDEVAPPC DEVD(mysystem)
RMTLOCNAME(mysystem)
CTL(ENTERPRISE)
TEXT('Device for HPRIP to mysystem')
CRTCTLAPPC CTLD(V7R1PROD) LINKTYPE(*HPRIP)
RMTINTNETA('###.###.###.###')
LCLINTNETA(###.###.###.###) RMTNETID(APPN)
RMTCPNAME(mysystem) CPSSN(*YES)
NODETYPE(*NETNODE) BEXROLE(*NETNODE)
TMSGRPNBR(1) TEXT('Connection to mysystem')

You need the controllers on both sides of the transaction.

That's enough to get you started. BTW if this looks a bit familiar to Larry Bolhuis, he wrote it, I just plagiarized it.




Jim Oberholtzer
Chief Technical Architect
Agile Technology Architects


On 9/6/2013 8:01 AM, Don Wereschuk wrote:
It appears that the SAVRSTOBJ is the best solution.(Thanks to all who suggested this) I tried to run a test and got an error on the transfer :

SAVRSTOBJ OBJ(A*) LIB(MYLIB) RMTLOCNAME(MYLOCNAME) OBJTYPE(*FILE) SAVACT(*LIB)
ACCPTH(*YES) MBROPT(*ALL) ALWOBJDIF(*ALL) RSTLIB(SPSL)

Route to specified location not found.

An error occurred during the SAVRSTOBJ operation.

We changed the location name using CHGNETA to be MYLOCNAME but this didn't seem to help. Does anyone know if I have to IPL for this to take effect or is there something else I have to do here?

As an Amazon Associate we earn from qualifying purchases.

This thread ...

Follow-Ups:
Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.