×
The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.
Kurt,
I agree with your partners request, I would make the same one. That
said, if you have seen no improvement, I suspect a different problem
than PTFs. Is this an LPAR box? Was the LPAR profile changed to use
the extra processor? Is there a high limit on the processor that is
less than (I think two based on your description) the number of
processors you had before adding one?
Yes, you can apply the cumulative and then go back and apply the group
for the TR later; But I highly suggest that in addition to the
Cumulative you apply the following list of groups as well:
PTF Group Text
SF99710 CUMULATIVE PTF PACKAGE C3037710
SF99709 GROUP HIPER
SF99708 GROUP SECURITY
SF99705 HARDWARE AND RELATED PTFS
SF99701 DB2 FOR IBM I
SF99627 7.1 ELECTRONIC SERVICES GROUP PTF
SF99572 JAVA
SF99368 IBM HTTP SERVER FOR I
SF99367 TCP/IP PTF
SF99366 PRINT PTFS
SF99362 BACKUP RECOVERY SOLUTIONS (even if you don't use
BRMS this is where all the save/restore PTFs are)
SF99145 PERFORMANCE TOOLS (if you have them)
The TR is SF99707 TECHNOLOGY REFRESH
The HIPER, and Hardware ones are the ones I would find most important in
this case, however if your taking the time to apply any Group you might
just as well get the entire batch. I'm not sure why you would not
want the TR group as well, unless there is something in the cover letter
that leads you to believe there is going to be a problem.
Jim Oberholtzer
Chief Technical Architect
Agile Technology Architects
On 5/15/2013 9:49 AM, Anderson, Kurt wrote:
So we've been really bad about PTFs. Our IBM BP is asking that we apply PTFs because after getting an additional core activated (from 1 to 2) we've noticed 0 improvement on the system.
So we finally ordered a cumulative PTF and we're looking at applying it. But then I thought, "What about technology refreshes?" It doesn't appear that the cume comes with a TR on it. Cume: C3037710
http://www-912.ibm.com/systems/electronic/support/s_dir/sline003.nsf/PSP%20Number%20View/SF98035
Are we safe to apply the Cume w/o a TR and then later investigate applying a Technology Refresh?
Thanks,
Kurt Anderson
Sr. Programmer/Analyst
CustomCall Data Systems, a division of Enghouse Systems Ltd
--
As an Amazon Associate we earn from qualifying purchases.