With older controllers you can run into this situation:
We had one hot spare and to protect the load source drive it has to be
in a load source capable position.
We lost a drive (not load source) and the hot spare activated taking the
place of the dead drive.
Now we were in a tricky position.
Just replacing the dead drive meant that our load source drive would not
be protected by the hot spare system.
We had to plan for a machine power down to move the drives around so we
could end up with our hot spare in a load source capable position.
Jerry
On 4/8/2013 9:08 AM, DrFranken wrote:
Per controller. With redundant cards such as on SAS each card wants to
have one.
- Larry "DrFranken" Bolhuis
www.frankeni.com
www.iDevCloud.com
www.iInTheCloud.com
On 4/8/2013 11:53 AM, Kirk Goins wrote:
Is the Hot Spare per controller or per Raid5 set?
Thanks
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact