That works! I assumed that "+7" would be interpreted the same as "7". But it uses the "+" to extend.
So logical and so simple - thanks!!
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx [mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Scott Mildenberger
Sent: Friday, October 26, 2012 11:19 AM
To: Midrange Systems Technical Discussion
Subject: RE: DDS REFFLD
From the reference manual:
A FIELD3 R +7
Put the +7 in the length position.
Scott
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Stone, Joel
Sent: Friday, October 26, 2012 10:13 AM
To: 'Midrange Systems Technical Discussion'
Subject: DDS REFFLD
Is it possible to reference a field in DDS but add 2 bytes to the
length?
For example:
SUBTOTAL R REFFLD(ExtendedPrice)
Length(+2)
Wishful thinking I'm sure.