Chuck,
I was in the process of looking through the job logs and history yesterday
when I had to leave (they kick me out at 1430!). But, as you surmised, the
ones I have looked at reveal nothing; even the one that applied to my
sessions. There was about an hour gap, which stopped when I started the
inquiry of the error message I was investigating and started up when
everything started shutting down.
By the way, I know that, when the system registers an abnormal end
(QABNORMSW = 1), this means that two IPLs will be necessary when applying
PTFs. But at V5R1 (sigh) I don't think that's going to happen. Is there
any other downside to leaving the system in this state, or should I re-IPL
to get iut back to normal?
Thanks.
Jerry C. Adams
IBM i Programmer/Analyst
--
A&K Wholesale
Murfreesboro, TN
615-867-5070
When both the MSD is not available and vlogs are lacking, poring over the
history log and joblogs for jobs that were active when the system was forced
down [possibly produced at end of the IPL] is sometimes fruitful; although
rarely in my experience, for an apparent hard-loop.
If vlogs are lacking, I always bump up the settings to allow much more data
[even if no more headers] so something should be there /next time/ something
bad occurs.
Regards, Chuck
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe,
or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a
moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.