× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



True.

More correctly: The last SCPF job not in ACTIVE status. Of course
that's really just a guess, the real answer is the SCPF job that was
active during the initial PTF application attempt.

Regards,

Scott Ingvaldson
Senior IBM Support Specialist
Midwest Region Data Center
Fiserv.


-----Original Message-----
From: rob@xxxxxxxxx [mailto:rob@xxxxxxxxx]
Sent: Wednesday, July 29, 2009 1:17 PM
To: Midrange Systems Technical Discussion
Subject: RE: Damaged PTF

<snip>
in OUTQ status?
</snip>
With V5R4 and above, if you have WRKSYSVAL QLOGOUTPUT set to *PND you
may see JOBLOG PENDING.
Job User Number Type -----Status---
QZRCSRVS QUSER 401096 PJ ACTIVE
QZRCSRVS QUSER 401095 PJ ACTIVE
QZRCSRVS QUSER 401067 PJ ACTIVE
QZRCSRVS QUSER 401050 PJ ACTIVE
QZRCSRVS QUSER 401048 PJ ACTIVE
QZRCSRVS QUSER 401047 PJ ACTIVE
QZRCSRVS QUSER 399396 PJ OUTQ
QZRCSRVS QUSER 397851 PJ OUTQ
QZRCSRVS QUSER 384944 PJ OUTQ
QZRCSRVS QUSER 384943 PJ OUTQ
QZRCSRVS QUSER 384942 PJ OUTQ
QZRCSRVS QYPSJSVR 400606 BCI JOBLOG PENDING
QZRCSRVS QYPSJSVR 399309 BCI JOBLOG PENDING
QZRCSRVS QYPSJSVR 398494 BCI JOBLOG PENDING

Rob Berendt
--
Group Dekko Services, LLC
Dept 01.073
Dock 108
6928N 400E
Kendallville, IN 46755
http://www.dekko.com





From:
"Ingvaldson, Scott" <scott.ingvaldson@xxxxxxxxxx>
To:
"Midrange Systems Technical Discussion" <midrange-l@xxxxxxxxxxxx>
Date:
07/29/2009 02:10 PM
Subject:
RE: Damaged PTF
Sent by:
midrange-l-bounces@xxxxxxxxxxxx



We have C9104/SI33310 installed on two LPARS and ready to apply on a
third.

On ours it looks like the path should be
/QIBM/ProdData/Access/Web2/classes/com/ibm/as400/webaccess/print/

We didn't have any issues with the install. Do you see anything
regarding SI33310 in the joblog for the last SCPF job in OUTQ status?

Regards,

Scott Ingvaldson
Senior IBM Support Specialist
Midwest Region Data Center
Fiserv.


-----Original Message-----
From: Mike Cunningham [mailto:mike.cunningham@xxxxxxx]
Sent: Wednesday, July 29, 2009 9:54 AM
To: 'Midrange Systems Technical Discussion'
Subject: Damaged PTF

We recently applied Cumulative Package C9104 for V5R4 and one of the
PTFs for iSeries access for the web got flagged as damaged. PTF is
SI33310. We have deleted and redownloaded this one PFT but it still
stays damaged. Job log points possible a missing IFS directory,
/QIBM/ProdData/Access/Web2/classes/ibm/as400/webaccess/print. We do not
currently use web access but do have it installed. Has anyone else
installed this PTF?


As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.