The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.
James,
At first I was going to say you probably didn't buy the extended
bezel, but thought that would be too mean.
First go to 02 and put the machine into manual (Change the N to an
M). Then you can get a 21. When done with the 21 function you go back to
02 and put it in Normal. You can do this during the middle of the day, as I
have a 100 times, and system continues to run just fine.
Pete
Pete Massiello
iTech Solutions
http://www.itechsol.com
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of James H. H. Lampert
Sent: Thursday, June 04, 2009 5:44 PM
To: Midrange Systems Technical Discussion
Subject: Re: SRC A900 2000 and yellow light
Pete Massiello wrote:
You just sign off DSP01 and leave it on the signon screen, and when you do
a
21, it will bring up the DST login screen. When you get out of DST, the
DSP01 signon screen will appear.
Wait a second . . . WHAT control panel function 21? I cycled through the
control panel functions, and they don't go past 19! Do I need to be in
restricted state? Do I need to be in manual IPL mode? Do I need to shut
down first?
--
JHHL
As an Amazon Associate we earn from qualifying purchases.