Charles, I'd do some testing on that before I believe the documentation.
Looking at the V6R1 provider, the value of the iDB2QuueryOptimizeGoal is
passed through to the MPConnection internal connection, and then down to
the CwbDc.Connect() method. And different values are passed depending on
that enum:
switch (piDB2Connection.QueryOptimizeGoal)
{
case iDB2QueryOptimizeGoal.FirstBlock:
this.m_QueryOptimizeGoal = 0xc6;
break;
case iDB2QueryOptimizeGoal.FullQuery:
this.m_QueryOptimizeGoal = 0xc1;
break;
default:
this.m_QueryOptimizeGoal = 0;
break;
}
Unfortunately when you pass to the CwbDc functions you're leaving
managed code -- no, the "managed" provider is not pure :( -- so I can't
follow it to well from there. I can tell that CWBDC.DLL does depend on
CWBCore.dll as does the ODBC driver, and CWBCore does expose several
connection related methods so my guess is they both eventually use the
same connection logic.
-Walden
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact