IMO, it is a good fit for all receivers including the security journal.
Under the covers, MTNJRN just does a CHGJRN and then has some routines to
determine how old a receiver is and will delete based on number of days.
For example, I prefer seeing thirty days of receivers rather than one
receiver with 30 days of activity. So, I set our scheduler to run the mtnjrn
command every day to change receivers and delete receivers after 32 days.
This also gets the receivers saved to tape for at least an additional 4
weeks based on our tape rotation schedule.
Mike Krebs
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Ketzes, Larry
Sent: Tuesday, July 17, 2007 12:06 PM
To: Midrange Systems Technical Discussion
Subject: RE: General Journal Question
Would there be any reason that this MTNJRN command should not be used on the
security journal?
Larry Ketzes | Senior iSeries System Administrator | AIG / ALICO - American
Life Insurance Company One ALICO Plaza, 600 N. King Street, AMIS |
Wilmington, DE 19801 | *:
302.594.2146 | 7: 302.830.4524| *: larry.ketzes@xxxxxxx
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of Mike Krebs
Sent: Tuesday, July 17, 2007 12:44 PM
To: 'Midrange Systems Technical Discussion'
Subject: RE: General Journal Question
There is an option in the cleanup functions to take care of those. GO
CLEANUP option 1. Read the help for which journals. If you have taatools,
there is MTNJRN that will take care of them as well as any user journals.
Mike Krebs
-----Original Message-----
From: midrange-l-bounces@xxxxxxxxxxxx
[mailto:midrange-l-bounces@xxxxxxxxxxxx] On Behalf Of John Candidi
Sent: Monday, July 16, 2007 7:54 AM
To: 'Midrange Systems Technical Discussion'
Subject: General Journal Question
Is it safe to delete journal receivers which have been detached for several
years in Qusrsys? I have a sample of some of them belowQSXJRN0022
QSXJRN0023 JOURNAL RECEIVER FOR PROBLEM DATABASE
QSXJRN1000 ditto
QSXJRN1001 ditto
QSXJRN2001 ditto
QSXJRN3001 ditto
QSXJRN3002 ditto
QSXJRN4002 ditto
John A Candidi
Rutgers Insurance Companies
IT Director - Iseries Manager
856-779-2274
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe,
or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a
moment to review the archives at
http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe,
or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a
moment to review the archives at
http://archive.midrange.com/midrange-l.
--
This is the Midrange Systems Technical Discussion (MIDRANGE-L) mailing list
To post a message email: MIDRANGE-L@xxxxxxxxxxxx To subscribe, unsubscribe,
or change list options,
visit:
http://lists.midrange.com/mailman/listinfo/midrange-l
or email: MIDRANGE-L-request@xxxxxxxxxxxx Before posting, please take a
moment to review the archives at
http://archive.midrange.com/midrange-l.
As an Amazon Associate we earn from qualifying purchases.