Corbett wrote:
Hi all,

I just added some 17G drives to a 520 with all 35G drives in it.  The drives
added ok, and I set them up in ASP 2 in a separate raid set (on a separate
controller), thinking that this would be better since they are of different
sizes.  However, the disk usage on these drives still shows 0% used.  I
thought that the drives being in ASP2 would not be an issue with spreading
the data.

Is there a problem with the way I configured these drives?  Could I/should I
have added them to ASP 1?  I doubt if I could have added them to the same
raid set, since they are of different size and in the expansion on a
different controller card.

Any advice on this?

Your help is appreciated.

William A.(Tony) Corbett

IBM Certified - AS/400 Developer

http://www.asresources.com

corbett@xxxxxxxxxxxxxxx

404-784-4737

fax: 678-935-5005



As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2026 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].