I have a BRMS question for those familiar. We currently have a CL that does our nightly processing and backups. We are going to replace the SAVLIB with STRBKUBRM. The CL already runs in batch and the STRBKUBRM cmd will be entered as SBMJOB(*no) so it will continue in the same CL. The problem is this: We need to monitor messages for the STRBKUBRM so that, if there is no tape loaded or a scratch tape is not loaded, the CL will continue and complete the rest of the steps it needs to complete. We do not want to replace the CL with a BRMS control group that has multiple *EXITs because it can be run with different parameters. What MONMSGs are needed or how else can we make this work? Thanks. NF
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2025 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].