How long should one wait on a SRC D90027C0 before switching to manual mode and doing a power down immediate? On an 840-23EA we have three partitions. We did a PWRDWNSYS *IMMED RESTART(*NO) on one of the partitions. According to the STRSST it was displaying SRC D90027C0 for about two hours. According to: http://publib.boulder.ibm.com/iseries/v5r2/ic2924/index.htm?info/rzamf/rzamfiplsrcfinder.htm D90027C0 means "System jobs are ending". At that time we used STRSST on the controlling partition to change that partition to manual, Did a power down immediately, then changed it back to normal. Then on the controlling partition we did a PWRDWNSYS *IMMED RESTART(*YES). Upon completion of the IPL on the controlling partition, we used STRSST to IPL the secondary partition. Rob Berendt -- "All creatures will make merry... under pain of death." -Ming the Merciless (Flash Gordon)
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].