----- Original Message -----
Sent: Thursday, July 26, 2001 6:57
PM
Subject: SLIP connection
If somebody can help me it will be great
:
I have an SLIP line (Win98 PC to AS400) on a
AS400/model 170/OS V4R5/last cum C1100450
few days ago the OS was in V4R3 and every was
working very well.
Today when I want to start the line (STRTCPPTP) I
get every time the following messages in Qsysopr (translated from French
to English) :
- Starting TCP/IP
point-to-point session for profile
SLIPANS.
- TCP/IP point-to-point session for profile SLIPANS
ended.
- software problem recorded for
QTOCPPSM
I tried to create a new (same) line directly in
V4R5 but I got the same problem.
Here is the configuration of the line
:
CRTLINASC LIND(my_line) RSRCNAME(my_rsc)
ONLINE(*NO)
+
INTERFACE(*RS232V24)
CNN(*SWTPP) VRYWAIT(*NOWAIT)
+
AUTOCALL(*NO) BITSCHAR(8)
PARITY(*NONE) STOPBITS(1)
+
DUPLEX(*FULL) ECHO(*NONE)
LINESPEED(19200) MODEM(*NORMAL) +
MODEMRATE(*FULL)
SWTCNN(*DIAL) AUTOANS(*NO)
+
AUTODIAL(*YES)
DIALCMD(*OTHER) SETMDMASC('*NONE')
+
CALLNBR(*NONE)
INACTTMR(*NOMAX) MAXBUFFER(1500)
+
THRESHOLD(*OFF)
FLOWCNTL(*HARDWARE) IDLTMR(1)
+
DSRDRPTMR(6)
AUTOANSTYP(*DTR) CTSTMR(25) RMTANSTMR(60)
+
CMNRCYLMT(2
5)
Here is the point to point *ANS profile
:
Name . . . . :
MY_PROFILE
Text . . . .
:
TCP/IP
information:
Protocol type . . . . . . . . . . . . . . . . . . . :
*SLIP
Local interface
address . . . . . . . . . . . . . . :
1.1.1.1
Remote IP address . . . . . .
. . . . . . . . . . . : 2.2.2.2
Maximum transmission unit . . . . . . . . . . . . . :
576
Allow
proxy ARP . . . . . . . . . . . . . . . . . . :
N
Add default route . . . . . . . . . . . . . . . . . :
N
Physical line
information:
Line description . . . . . . . . . . . . . . . . .
: MY_LINE
Line type . . . . . . .
. . . . . . . . . . . . . . :
*ASYNC
Autocreate controller
and device . . . . . . . . . :
Y
Modem
information:
Use a modem . . . . . . . . . . . . . . . . . . . . :
Y
Modem information
name:
MultiTech 28800 Multimodem
Modem initialization
string:
AT&D2&C1X4V1Q0S7=70$BA0$SB19200&S1
Modem reset
string:
AT&F
Modem answer
command:
ATS0=2
Script source
information:
Use connection dialog script . . . . . . . . . . .
:
Y
Member . . . . . . . . . . . . . . . . . .
. . . : ANSWIN95
File . . . . . . . . . . . . . . . . . . .
. . . : QATOCPPSCR
Library . . . . . . . . . . . . . . .
. . . . . : QUSRSYS
ASCII character set identifier . . . . . .
. . . : 00819
Local system
security:
Allow IP datagram forwarding . . . . . . . . . . .
:
N
System access authorization list . . . . . . . . .
:
AUTSLIP
Thank for your
help,
___________________________________________________________________
Eric
PANISSARD
Responsable du Département iSeries 400
INFORMATIQUE
DE TAHITI
6, rue Leboucher - BP 1744 - 98713 PAPEETE
TAHITI - POLYNESIE
FRANCAISE
Tel : (689) 54 40
40 Fax : (689) 43
37 90
E-mail : EPanissard@idt.pf
___________________________________________________________________