Al,

Do not use a source physical file for the target of a CPYSPLF.  Use a straight
PF (CRTPF).

It appears that others have suggested more high level solutions for your
problem, so I'll stop with that.  But if you end up reinventing the wheel, you
also need to be aware of the CTLCHAR parameter.

Dan Bale
IT - AS/400
Handleman Company
248-362-4400  Ext. 4952

-------------------------- Original Message --------------------------
This is so embarrassing & maybe even funny after I get past the crisis.

When we copy a spool file into a source file, how do we get the full width of
the spool file report without anything chopping off?  No, I have not yet
looked at the archives, but I do plan to test David's new access.

I have been nagging management for an eternity to get one of those software
packages that sends 400 data to PC & to web & etc. because it seems to me
that we have several people working full time transcribing stuff between
different computers & using old fashioned scissors to get reports to
photocopy machine to fax machine.

So a few years ago I managed to sell them on using Monarch to send year end &
physical inventory reports via e-mail attachment to our auditors, and lots of
people were happy with this.  Now next week is physical inventory & fiscal
year end & come to find out they can't get Monarch to work.

Hey says I, Monarch comes with tech support & their web site is
www.datawatch.com in case the phone #s in our ancient manual have changed,
since we got this on Win 3.1 ... the PC has gone to 95 then 98 & had some
hard disk crash & all the hardware replaced over time & it used to talk to
the 400 via 5250 emulation & now via some NT WAN which fakes out the 400 into
thinking it is a local work station controller & also the 400 is a different
box serial # & OS upgraded, so it only stands to reason that we need some
kind of upgrade to our Monarch.

But they say we have left it too late to resolve this.
Well says I, you may be judging Monarch by certain other outfits whose tech
support is in name only, there are other places with excellent tech support
like IBM ASNA & KSAI.

Bottom line, I get to write some software that does what Monarch does, and
they need it yesterday.

I created a *SRC file 132 bytes wide & into a member of it, I imported a test
spool report, and it was looking good except I only got the first 120
characters because of IBM tracking last time some line created or changed.
Ok, no problem, I thought.
I created a *SRC file 144 bytes wide (132 + allow 12 for the missing after
120) & into a member of it, I imported a test spool report, and it was
looking good except I only got the first 120 characters of each line.  For
software type I used XPERIMENT because I did not want to use some official
IBM source type that is like 80 or 96 wide & I do not know how to look at
what all there in sizes to find goodies like OCL36 is 120 wide, but I need
more than that.

So one question is whether when we import a spool file into a source file if
120 is the ceiling, or if there is some simple thing I have overlooked to get
it all in there for 132 print positions & also we have some 15 to inch 198
character reports.

For my next experiment, I took one of the reports they were interested in &
copied the program, substituting a 132 wide data file (I had to define it
with DDS) for the printer file & found I could not use overflow or vertical
spacing, but I could insert blank lines, which is something lost by the spool
file approach.  This is working but it needs some packaging so that every
time they run it - data to a different member name.  Also I want to find out
if it is Ok with them that the page headers file only one time, then we have
10,000 file lines of detail report until final totals.

My PC buddy will next see if he can get the files I created to our auditors &
if the non-Monarch format is satisfactory to them.  He has transmitted other
400 files at other times to various places, but I do not know the
circumstances or the tools he is using.

MacWheel99@aol.com (Alister Wm Macintyre) (Al Mac)
AS/400 Data Manager & Programmer for BPCS 405 CD Rel-02 mixed mode (twinax
interactive & batch) @ http://www.cen-elec.com Central Industries of
Indiana--->Quality manufacturer of wire harnesses and electrical
sub-assemblies - fax # 812-424-6838
+---
| This is the Midrange System Mailing List!
| To submit a new message, send your mail to MIDRANGE-L@midrange.com.
| To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com.
| To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: david@midrange.com
+---

As an Amazon Associate we earn from qualifying purchases.

This thread ...


Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.