Chris: The 6512 IOP can be configured to support 16 arms in 2 RAID sets. "Handling" 16 arms in a write-intensive environment is another question altogether. Beware: the PCI disk IOPs support a maximum of 15 disk arms. Richard Jackson mailto:richardjackson@richardjackson.net www.richardjacksonltd.com Voice: 1 (303) 808-8058 Fax: 1 (303) 663-4325 -----Original Message----- From: owner-midrange-l@midrange.com [mailto:owner-midrange-l@midrange.com]On Behalf Of Chris Bipes Sent: Monday, July 17, 2000 2:04 PM To: 'MIDRANGE-L@midrange.com' Subject: RE: AS/400 UPGRADE We had the same system. 510/2143. We also mirrored the two internals just like you are. You did not mention which IOP the other 10 drives are attached to, Just the load source which are internal drives. If you have the 6512 it can handle 16 - 6607 drives with two raid sets of 8 drives each. That is what we had on the 510 and brought to our 720. Here is the WRKHDWRSC *STG listing from our 720. It was the same on the 510. SI01 6512-001 Operational Storage Controller DC24 6607-072 Operational Disk Storage Controller DC25 6607-072 Operational Disk Storage Controller DC22 6607-072 Operational Disk Storage Controller DC23 6607-072 Operational Disk Storage Controller DC06 6607-072 Operational Disk Storage Controller DC07 6607-072 Operational Disk Storage Controller DC08 6607-072 Operational Disk Storage Controller DC09 6607-072 Operational Disk Storage Controller DC10 6607-072 Operational Disk Storage Controller DC11 6607-072 Operational Disk Storage Controller DC12 6607-072 Operational Disk Storage Controller DC13 6607-072 Operational Disk Storage Controller DC26 6607-072 Operational Disk Storage Controller DC27 6607-072 Operational Disk Storage Controller DC28 6607-072 Operational Disk Storage Controller DC29 6607-072 Operational Disk Storage Controller Christopher K. Bipes mailto:ChrisB@Cross-Check.com Sr. Programmer/Analyst mailto:Chris_Bipes@Yahoo.com CrossCheck, Inc. http://www.cross-check.com 6119 State Farm Drive Phone: 707 586-0551 x 1102 Rohnert Park CA 94928 Fax: 707 586-1884 If consistency is the hobgoblin of little minds, only geniuses work here. Karen Herbelin - Readers Digest 3/2000 -----Original Message----- From: oludare [mailto:oludare@ix.netcom.com] Sent: Monday, July 17, 2000 12:40 PM To: MIDRANGE-L@midrange.com Subject: Re: AS/400 UPGRADE Hi Richard, Could you, if you know, how to find out if my IOP is incapable of supporting more than 1 RAID set. Are you also claiming that I have 48gig of DASD on my 510? If so, could you explain the use of the mirrored DASD. Below you'll find detail information on my IOP. +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +--- +--- | This is the Midrange System Mailing List! | To submit a new message, send your mail to MIDRANGE-L@midrange.com. | To subscribe to this list send email to MIDRANGE-L-SUB@midrange.com. | To unsubscribe from this list send email to MIDRANGE-L-UNSUB@midrange.com. | Questions should be directed to the list owner/operator: david@midrange.com +---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.