|
DESCRIPTION OF PROBLEM FIXED FOR APAR MA24927 : ----------------------------------------------- The values returned for the following programming interfaces may be incorrect: MATRMD MI Interactive Utilization Data Option Hex 1E - Offset Hex 10 Interactive threshold Offset Hex 12 Interactive limit QYHCHCOP - CommmercialProcessingWorkloadTotal CommercialProcessingWorkloadInteractive CORRECTION FOR APAR MA24927 : ----------------------------- The problem will be fixed. Correct CPW numbers will be returned.
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.