>>>The issue, I think I've heard, is when more than 1 user have the same >>>CURLIB. Have you heard anything like that? This is because CODE communications stores the connection information such as the ip address in the STRCODE *USRSPC which is created in the *CURLIB. If more than one user is using the same *CURLIB, the same *USRSPC will be updated with the last user connected. Best regards, Hak _______________________ Hak Lui AS/400 AD, IBM Canada Ltd. e-mail: haklui@ca.ibm.com
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].