|
Hi Penny,
We had the same problem when we first brought it up. The way we corrected it, and correct me if I'm wrong guys, is to create individual libraries and set them up as our *CURLIB. This way, when we brought up code/400 it would create the STRCODE *USRSPC in the current library rather than our default, which was QGPL. Obviously, with everyone set to default, everyone was accessing the same STRCODE in QGPL and message were routed to the wrong workstation. This should take care of your problem. We set up individual libraries specifically or the STRCODE, because we sometime copy files into out personal libraries for testing, so we didn't want them as or *CURLIB. If you don't have that problem, then just set your *CURLIB to your personal lib and you should be good to go.
Chris
-----Original Message-----
From: Penny_Lancor.OGIDM@oakdene.com
[mailto:Penny_Lancor.OGIDM@oakdene.com]
Sent: Wednesday, May 09, 2001 1:38 PM
To: CODE400-L@midrange.com
Subject: RE: Option in PDM for starting up code/400
I have entered the PDM command exactly as you listed (excluding the S30),
but the code editor still starts up on a co-worker's desktop. Is anyone
using the PDM option when more than one user is using CODE/400?
Chris Proctor
<cproctor@gartsports.c To: "'CODE400-L@midrange.com'"
om> <CODE400-L@midrange.com>
Sent by: cc:
code400-l-owner@UUCPHO Subject: RE: Option in PDM for starting up
ST.MCS.NET code/400
05/09/01 08:58 AM
Please respond to
CODE400-L
Hi Penny,
I'm honestly not well versed on all the parameters of the codeedit command,
but I do have it working from PDM using the following command. Why don't
you try it and see if it works for you. Good luck!
Chris
call qcode/evfcfdbk parm('37' 'Y' 'S30' '<LOCAL> CODEEDIT "<S30>&L/&F(&N)"
/M Y /N')
I'm using S3o rather than OS400A, so you'd have to change that for your
command.
-----Original Message-----
From: Penny_Lancor.OGIDM@oakdene.com
[mailto:Penny_Lancor.OGIDM@oakdene.com]
Sent: Wednesday, May 09, 2001 7:30 AM
To: CODE400-L@midrange.com
Subject: RE: Option in PDM for starting up code/400
I am trying to implement the PDM option for starting code/400 via PDM.
When I take the new option, either of two things happen:
1. The PDM session stays inhibited for about 20 seconds, and then does
nothing,
or,
2. The code/400 window starts up on a co-worker's desktop
My PDM option commands looks like this:
Command . . . . . . . . . /* CODE Edit Member */ CALL
PGM(QCODE/EVFCFDBK) PARM('37' 'Y' 'OS400A' '<LOCAL> CODEEDIT "<OS400A>&L/&F
(&N)"')
I have an unique current library.
I have set the AS400 server information on my PC
The communications server is running on my PC
Any help would be greatly appreciated.
Regards,
Penny Lancor
Technical Services
Oakdene Group, Inc.
"Barry W. Hoffman"
<bwhoffman@natsem.com> To:
CODE400-L@midrange.com
Sent by: cc:
"'cproctor@gartsports.com'"
code400-l-owner@UUCPHO <cproctor@gartsports.com>
ST.MCS.NET Subject: RE: Option
in PDM for starting up
code/400
04/24/01 02:39 PM
Please respond to
CODE400-L
Chris,
Here are the 3 PDM options that I use:
CB:
CALL QCODE/EVFCFDBK PARM('37' 'Y' 'OS400' '<LOCAL> CODEBRWS "<>&L/&F&N)"')
CD:
CALL QCODE/EVFCFDBK PARM('37' 'Y' 'OS400' '<LOCAL> CODEDSU "<>&L/&F&N)"')
CE:
CALL QCODE/EVFCFDBK PARM('37' 'Y' 'OS400' '<LOCAL> CODEEDIT "<>&L/&F
(&N)"')
The third parm needs to be the name of your Code/400 server. Also note &L
not &I.
Barry Hoffman
National Seminars
-----Original Message-----
From: Chris Proctor [mailto:cproctor@gartsports.com]
Sent: Tuesday, April 24, 2001 1:03 PM
To: CODE400-L (E-mail)
Subject: Option in PDM for starting up code/400
Hi all,
I'm a newbie to code/400, but I read an email yesterday about setting up
an option to start code/400 from PDM. The email said to set up the option
like this:
call qcode/evfcfdbk parm('37' 'Y' 'PCTCI' '<LOCAL> CODEEDIT "<> &l/&F(&N)"
/M Y /N')
So, all excited (it doesn't take much!) I tried it and it didn't work! :
-( In fact it didn't do anything at all.....no error message, NOTHING!
This is the first time we've ever tried this, so I'm not even sure the
AS/400 is setup properly (if anything has to be configured on it). Can
someone possibly point me in the right direction?
Thanks,
Chris Proctor
Manager of Systems Integration
MIS
<<...OLE_Obj...>>
1060 Broadway
Denver, CO 80203
Phone (303) 863-2280
Fax (303) 863-2263
mailto: cproctor@gartsports.com
+---
| This is the CODE/400 Mailing List!
| To submit a new message, send your mail to CODE400-L@midrange.com.
| To subscribe to this list send email to CODE400-L-SUB@midrange.com.
| To unsubscribe from this list send email to CODE400-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: larry@paque.net
+---
+---
| This is the CODE/400 Mailing List!
| To submit a new message, send your mail to CODE400-L@midrange.com.
| To subscribe to this list send email to CODE400-L-SUB@midrange.com.
| To unsubscribe from this list send email to CODE400-L-UNSUB@midrange.com.
| Questions should be directed to the list owner/operator: larry@paque.net
+---
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.