On 08/06/2010, at 6:53 AM, Nancy Barney wrote:
I am trying to read a tab delimited file, which was created by Excel.
This ILE COBOL Version 6, Release 1.
I have the tab character in working storage defined as:
01 WS-HEX-TAB PIC X(01) VALUE X"09".
That's an ASCII Horizontal Tab. Is the data still in ASCII?
You say it was created by Excel but then it has to transferred to the
host. That transfer probably converted from ASCII to EBCDIC therefore
the Tab code-point will be different (X'05' in CCSID 37 which
is likely what you're using presuming you're in the US).
If the data is in a database file use DSPPFM to view then press
F10=Hex then F11=Over/Under, locate the tab and see its corresponding
hexadecimal code-point.
If the data is in a stream file then use DSPF to view and press
F10=Hex. This command doesn't have an Over/Under option so locating
the Tab is a bit harder.
If the data *IS* still ASCII then you probably want it in EBCDIC so
either transfer in text mode rather than binary, or transfer to a
stream file and use CPYFRMIMPF to convert and extract.
Regards,
Simon Coulter.
--------------------------------------------------------------------
FlyByNight Software OS/400, i5/OS Technical Specialists
http://www.flybynight.com.au/
Phone: +61 2 6657 8251 Mobile: +61 0411 091 400 /"\
Fax: +61 2 6657 8251 \ /