Kelly,
It might have something to do with this:
https://www.ibm.com/docs/en/i/7.2?topic=ssw_ibm_i_72/apis/qsyrgap.html
HTH,
Mark
> On Wednesday, November 22, 2023 at 11:33:15 AM EST, Kelly Beard <kenverybigliar@xxxxxxxxx> wrote:
gsk_environment_init() failed with rc = 6002 and errno = 0.
rc of 6002 means Application identifier is not registered to use TLS.
I don't really know what this means. It sounds like I need to do something
on the 400 but at the moment I don't know what that means. I think its
failing or not set up correctly here:
rc = gsk_attribute_set_buffer(my_env_handle, GSK_IBMI_APPLICATION_ID,
"MY_CLIENT_APP", 13);
Its been a few days since I've gotten back to this, so progress comes in
waves.
Anyway, thanks!
As an Amazon Associate we earn from qualifying purchases.
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact