× The internal search function is temporarily non-functional. The current search engine is no longer viable and we are researching alternatives.
As a stop gap measure, we are using Google's custom search engine service.
If you know of an easy to use, open source, search engine ... please contact support@midrange.com.



the another very interesting action is verify theECM tables (TOHB,
TOLB, TELB, TPEC) size.

regards,

2010/4/15 <jdyer@xxxxxxxxxx>:
There are parms in the ECA setup for this.

There are 2 jobs/ECAs ... the Collection Control Manager and the Dispatch
Manager ... both have entries in the ECA option of the ECM menu.  For each
one take option 15 (parameters).




From the documentation ...

If the LPFCTTIME parameter is present and contains a value other than
000000, the Collection Control Manager goes to sleep until that time. If
the time held in this parameter is later than the current time at the end
of the previous processing cycle, processing is delayed until the next day
at the specified time. When this scheduling condition is true, the
Collection Control Manager does not look at the number of loops specified,
but continues to cycle until some other process stops the Collection
Control Manager.

If the above condition is not true, and the LPFCTSEC parameter is greater
than 000000 and the LPFCTLOOP parameter is equal to 000000, the Collection
Control Manager goes to sleep for the specified number of seconds at the
end of each processing cycle. When this scheduling condition is true the
Collection Control Manager does not look at the number of loops specified,
but continues to cycle until some other process stops the Collection
Control Manager.

If the above conditions are not true, and the LPFCTSEC parameter is
greater
than 000000 and the LPFCTLOOP parameter is greater than 000000, the
Collection Control Manager goes to sleep for the specified number of
seconds at the end of each processing cycle, At the end of each cycle, the
Collection Control Manager subtracts 1 from the number of cycles specified
when the Collection Control Manager started. When the number of cycles
reaches 0, the Collection Control Manager ends.

When none of the above conditions are true, the Collection Control Manager
does not cycle and discontinues further processing.

The LPFCTLOOP parameter is evaluated when the Collection Control Manager
is
started. The LPFCTSEC and LPFCTTIME parameters are re-evaluated at the end
of each processing cycle. Therefore it is possible to adjust these two
parameters without ending the Collection Control Manager processing. This
should only be done while the Collection Control Manager is asleep and
there is no chance that the Collection Control Manager processing could
continue while the record is being maintained.  0 to 999999


___________
Karyn Young
Information Management Consultants, Inc.
kyoung@xxxxxxxxxx
office 812.421.0045  ext 204
cell 812.205.5200




From:
Norman.Boyd@xxxxxxxxxxxxxxxxx
To:
BPCS ERP System <bpcs-l@xxxxxxxxxxxx>
Date:
04/15/2010 06:47 AM
Subject:
Re: [BPCS-L] BPCS ECM Question
Sent by:
bpcs-l-bounces+jdyer=imcedi.com@xxxxxxxxxxxx



Rob,

This may or may not be the case.  Check your Robot job to see if someone
entered parameters there to end the job IF it is running after a certain
amount of time.

Good luck.

Norman K. Boyd
MIS Administrator
Showa Aluminum Corp. of America

CONFIDENTIALITY NOTICE: This e-mail message is intended only for the
person or entity to which it is addressed and may contain confidential
and/or privileged material. Any unauthorized review, use, disclosure or
distribution is prohibited. If you are not the intended recipient, please
contact the sender by reply e-mail and destroy all copies of the original
message. If you are the intended recipient but do not wish to receive
communications via email, please advise the sender immediately.





Re: [BPCS-L] BPCS ECM Question

SKumaran
to:
BPCS ERP System
04/14/2010 04:10 PM


Sent by:
bpcs-l-bounces+norman.boyd=showaaluminum.com@xxxxxxxxxxxx
Please respond to BPCS ERP System






Rob,

ECM (Electronic Commerce Manager) which brings in our customer orders to
BPCS via EDI ( Electronic Data Interchange).

We have the ECM startup jobs in ROBOT but the problem is that it ends
itself  after 480 minutes. The job log does not show errors.

There should be a parameter some where in BPCS ECM files that is set with
a timer to end the jobs.

Thanks

Suresh

--
This is the BPCS ERP System (BPCS-L) mailing list
To post a message email: BPCS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/bpcs-l
or email: BPCS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/bpcs-l.

Delivered-To: norman.boyd@xxxxxxxxxxxxxxxxx

--
This is the BPCS ERP System (BPCS-L) mailing list
To post a message email: BPCS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/bpcs-l
or email: BPCS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/bpcs-l.

Delivered-To: jdyer@xxxxxxxxxx




______________________________________________________________

Confidentiality Notice: This E-mail (including attachments) is confidential and the property
of Information Management Consultants, Inc. (IMC).

If you are not the intended recipient:
Reading, copying, disclosure or any action based on this message is prohibited.  IMC retains
copyright and intellectual property rights and objects to misuse.

IF YOU HAVE RECEIVED THIS E-MAIL IN ERROR, PLEASE CONTACT THE SENDER
TO ADVISE OF THE ERROR AND PERMANENTLY DELETE THIS E-MAIL.

______________________________________________________________

--
This is the BPCS ERP System (BPCS-L) mailing list
To post a message email: BPCS-L@xxxxxxxxxxxx
To subscribe, unsubscribe, or change list options,
visit: http://lists.midrange.com/mailman/listinfo/bpcs-l
or email: BPCS-L-request@xxxxxxxxxxxx
Before posting, please take a moment to review the archives
at http://archive.midrange.com/bpcs-l.

Delivered-To: renatog.konda@xxxxxxxxx






As an Amazon Associate we earn from qualifying purchases.

This thread ...

Replies:

Follow On AppleNews
Return to Archive home page | Return to MIDRANGE.COM home page

This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact [javascript protected email address].

Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.