If the materials are backflushing from the wrong warehouse, check the
default Stocking Warehouse in CIC. Even if you identify an item as
'facility wide alloc/backflush' = no, the logic will still use the Stocking
warehouse. In your example these should all be 'AA'.
Kent Van Horn
DS Solutions, Inc.
(402) 533-2312
kvanhorn@xxxxxxxxxxxxxxxxxx
-----Original Message-----
From: bpcs-l-bounces+lkvanhorn=huntel.net@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+lkvanhorn=huntel.net@xxxxxxxxxxxx] On Behalf Of
Larenzo Alexander
Sent: Friday, November 20, 2009 9:35 AM
To: BPCS ERP System
Cc: bpcs-l-bounces+p.deveau=bluelineinc.com@xxxxxxxxxxxx; BPCS Forum Post
Subject: Re: [BPCS-L] Réf : Backflushing From Wrong Location?
No, we haven't tried the force location in JIT110. But it looks like we may
should try to change the "allocatable flag" in the location master for all
locations to 0 (no) except warehouse 'AA' location BLANK(backflush
warehouse). If that doesnt work then we may have to try the force locations.
Thanks
________________________________
From: "P.Deveau@xxxxxxxxxxxxxxx" <P.Deveau@xxxxxxxxxxxxxxx>
To: BPCS ERP System <bpcs-l@xxxxxxxxxxxx>
Cc: bpcs-l-bounces+p.deveau=bluelineinc.com@xxxxxxxxxxxx; BPCS Forum Post
<bpcs-l@xxxxxxxxxxxx>
Sent: Fri, November 20, 2009 9:46:07 AM
Subject: [BPCS-L] Réf : Backflushing From Wrong Location?
Have you try to use the force location in option JIT110.
Pierre
Larenzo Alexander <larenzo_alexander@xxxxxxxxx>
Envoyé par : bpcs-l-bounces+p.deveau=bluelineinc.com@xxxxxxxxxxxx
20.11.2009 09:15
Veuillez répondre à
BPCS ERP System <bpcs-l@xxxxxxxxxxxx>
A
BPCS Forum Post <bpcs-l@xxxxxxxxxxxx>
cc
Objet
[BPCS-L] Backflushing From Wrong Location?
Hello All,
I posted a post in the past about backflushing and I thought we found the
solution to this issue but I must have been dreaming. LOL
We have 1 warehouse called 'AA' with a BLANK location and other locations.
Everything should get backflushed from the BLANK location only. The other
locations within warehouse 'AA' is only for tranfers.
For some reason we have component items that started to back flush from
the wrong locations other than the BLANK location in warehouse 'AA' all of
a sudden. The only change I can think of close to time it sarted happen
was the installation of a new System i5.
* Checked the Shop Orders for the FG Item and the Warehouse/Location is
correct. (AA-BLANK)
* Checked the Item Master & Facility Planning and the warehouse/Location
is correct. (AA-BLANK)
* Checked the Location Master for each location and the settings are the
same for all locations in 'AA' included Blank. This may be the problem but
we never changed this and they seem to work in the beginning.
- Allocatable = 1 (Yes) Allow Automatic Allocations
- Location usage = 1 (standard)
* I did notice that each part in question had a parent that was a phantom.
Not sure if the phantom blow through had something to do with it.
If anyone know something I miss to check it would be greatly appreciated.
(TGIF)
As an Amazon Associate we earn from qualifying purchases.
This thread ...
Re: Backflushing From Wrong Location?, (continued)
This mailing list archive is Copyright 1997-2024 by midrange.com and David Gibbs as a compilation work. Use of the archive is restricted to research of a business or technical nature. Any other uses are prohibited. Full details are available on our policy page. If you have questions about this, please contact
[javascript protected email address].
Operating expenses for this site are earned using the Amazon Associate program and Google Adsense.