yes
-----Original Message-----
From: bpcs-l-bounces+dfinnerty=flanderscorp.com@xxxxxxxxxxxx [mailto:bpcs-l-bounces+dfinnerty=flanderscorp.com@xxxxxxxxxxxx] On Behalf Of Gregory A. Garner
Sent: Monday, November 09, 2009 4:02 PM
To: 'BPCS ERP System'
Subject: Re: [BPCS-L] AP check print spool file question
I don't know how to set the report overrides in BPCS. But it seems that is
where the issue is.
Is your forms package merge of spool and form being triggered based upon the
form type for all your forms printing?
Gregory A. Garner, President
Garner Data Systems, Inc
4270 Grand Teton Parkway
Suwanee, GA 30024
p - 770.845.9636 f - 866.895.2683
http://www.GoLiveCycle.com
-----Original Message-----
From: bpcs-l-bounces+ggarner_gds=mindspring.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+ggarner_gds=mindspring.com@xxxxxxxxxxxx] On Behalf Of
Dee Finnerty
Sent: Monday, November 09, 2009 3:29 PM
To: BPCS ERP System
Subject: Re: [BPCS-L] AP check print spool file question
I need the form type to be whatever is defined in the overlay software.
So an override print file command needs to affect the spool file that
Needs to be matched up to the form. Otherwise the default is *STD.
OVRPRTF FILE(QSYSPRT) OUTQ(&OUTL/&OUTQ) +
FORMTYPE(ORDER) +
SECURE(*YES)
I created a little cl that is suppose to do the override and put an entry
Into the OLM145D1 to call the cl which in turn does the override and
Calls ORD508B. However I am not getting any spoolfiles. No errors
Or dumps and no spoolfiles, just a joblog that has no useful information.
-----Original Message-----
From: bpcs-l-bounces+dfinnerty=flanderscorp.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+dfinnerty=flanderscorp.com@xxxxxxxxxxxx] On Behalf Of
Gregory A. Garner
Sent: Monday, November 09, 2009 3:03 PM
To: 'BPCS ERP System'
Subject: Re: [BPCS-L] AP check print spool file question
What overrides do you mean?
Gregory A. Garner, President
Garner Data Systems, Inc
4270 Grand Teton Parkway
Suwanee, GA 30024
p - 770.845.9636 f - 866.895.2683
http://www.GoLiveCycle.com
-----Original Message-----
From: bpcs-l-bounces+ggarner_gds=mindspring.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+ggarner_gds=mindspring.com@xxxxxxxxxxxx] On Behalf Of
Dee Finnerty
Sent: Monday, November 09, 2009 2:39 PM
To: BPCS ERP System
Subject: Re: [BPCS-L] AP check print spool file question
How do you get the overrides to the forms objects without modifying the
programs in BPCS?
-----Original Message-----
From: bpcs-l-bounces+dfinnerty=flanderscorp.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+dfinnerty=flanderscorp.com@xxxxxxxxxxxx] On Behalf Of
Gregory A. Garner
Sent: Sunday, November 08, 2009 10:35 AM
To: 'BPCS ERP System'
Subject: Re: [BPCS-L] AP check print spool file question
Regardless of the page size on input, you can map the spool information to
an 8.5X11.5 page. I have implemented electronic forms with BPCS AP checks
for several clients and have never had to modify the program.
Gregory A. Garner, President
Garner Data Systems, Inc
4270 Grand Teton Parkway
Suwanee, GA 30024
p - 770.845.9636 f - 866.895.2683
http://www.GoLiveCycle.com
-----Original Message-----
From: bpcs-l-bounces+ggarner_gds=mindspring.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+ggarner_gds=mindspring.com@xxxxxxxxxxxx] On Behalf Of
Dan Sweeney
Sent: Sunday, November 08, 2009 9:17 AM
To: BPCS ERP System
Subject: Re: [BPCS-L] AP check print spool file question
I have not used ACOM but I have experience with other forms packages and in
every case I have always modified the BPCS code to fit the custom form.
This is especially true for A/P checks.
The spool file needs to be labeled the same as the originating program in
this case ACP670B - good luck!
Dan Sweeney - Sr Technical Consultant
PHOENIX Business Consulting, Inc.
Cell: 860.490.6712
www.phoenixbcinc.com
-----Original Message-----
From: bpcs-l-bounces+dsweeney=phoenixbcinc.com@xxxxxxxxxxxx
[mailto:bpcs-l-bounces+dsweeney=phoenixbcinc.com@xxxxxxxxxxxx] On Behalf Of
Kathy Steigerwalt
Sent: Saturday, November 07, 2009 12:46 PM
To: bpcs-l@xxxxxxxxxxxx
Subject: [BPCS-L] AP check print spool file question
Hi,
I am very new to BPCS. We are on version 6 with As/set. We are going to
implement ACOM laser check printing. Currently we use pre-printed pin
fed
check stock, with the stub on top of the check form. Our BPCS AP print
program does the usual page overflow for multiple AP invoices that do not
fit on the stub with the Voided check(s). The current page size of the
AP
check (stub & check) is not 8.5 x 11 but smaller. As/set compiles can
take 45mins at a minimum to some taking most of the day. That being
said
I prefer to do the new MICR check printing without modifying the code.
Could I generate the values of a check run with something as simple as a
AS/400 query? Or perhaps ACOM can merge the current spool file and
produce 8.5 x 11 MICR checks? Has anyone implemented ACOM MICR checks
without modifying the BPCS print program? I appreciate any help or
thoughts.
Thank you.
KAS
A BPCS newbie