Hello
Yes & no.
As for latest BMR of ECM628B5
06May02 0060797 Correct creation of EWR (prevent blank values)
Correct Validation of Lot for Multiple Item/Lot #
Correct creation of EWR for Kit Items (Components)
Correct WRSKIN value when Loads are processed. A1EWR
24Oct03 0066413 Change WSID from ECM to system WSID for call to
ORD570 to be able to print documents.
19Dec03 0066737 When non-component move shipped qty to alloc. qty
23Dec05 0070575 Correct ECM628B5 not create load and B transaction.
Subr. changed: A0INIT, A0ROA, A0EWR
The program calls also ORD570B, so ECM628 itself do not update, BUT from TPEB
.... Via EWR & ORD570B it does.
Only to pay attention on how 70575 works
Thanks
Regards
Davide
-----Original Message-----
From: bpcs-l-bounces+davide.roveda=infor.com@xxxxxxxxxxxx
[
mailto:bpcs-l-bounces+davide.roveda=infor.com@xxxxxxxxxxxx] On Behalf Of
BBilgen@xxxxxxx
Sent: martedì 19 giugno 2007 0.30
To: bpcs-l@xxxxxxxxxxxx
Subject: Re: [BPCS-L] BPCS-L Digest, Vol 5, Issue 130
Lubos,
The base ECM628 adaptor in BPCS version 6.1.01 does not post anything to
BPCS. It just validates the data and then stops processing the transaction.
In
order to make this work, you will need to add a new function into the
program stack that will load the pick confirm work files, allocate the
quantities/lots and then run ORD570B to update the order and relieve the
inventory. If
you would like to discuss this further, please feel free to contact me off
line.
Barbara Bilgen
_bbilgen@xxxxxxxx (
mailto:bbilgen@xxxxxxx)